Click on a Menu below to find additional information about how, where, and what Spilfyter® Spill Control Products to use in what situation:
 
_
_Click below for our Products:
CHEMICAL/WASTEWATER CLASSIFIERS: (BACK TO TOP) Download in PDF:

Chemical and Wastewater Classifier Strips and Charts are the perfect method for distinguishing risks in unknown spilled liquids and quickly assist the user in classifying the spill for proper treatment. Chemical and Wastewater Kits and Stations are ideal for personnel who respond to unknown liquid spills on a regular basis.

Q: HOW DO I USE SPILFYTER® CLASSIFIER STRIPS?

1.Keep Classifier dry until ready to use to avoid premature activation of the test strips. Avoid touching or contaminating test area on strip.

2.Wastewater tests can be conducted in stages or all at once by removing one or more of the TABS.

3.Fan Classifier in gas zone just above the level of solution to be tested. Observe test results.*

4.Dip Classifier vertically into solution (test end first).

5.Leave test strip in solution for 30 seconds, swishing if possible.

6.After removing test strip from solution IMMEDIATELY LAY FLAT on Color Chart.**

*Classifier Strips are intended to be used for one wet testing procedure. Testing for vapors is considered part of a single test.

** If Classifier is dipped or held in the incorrect position, bleeding from Test #1 may interfere with tests #2, #4 and/or #5.

Q: WHAT ABOUT STABILITY AND STORAGE?

Remove only as many strips as are required and reseal the container immediately after use. Do not touch test papers! Avoid exposing the strips to sunlight and moisture. Store the container in a cool dry place 68°F or 20°C. Original color of test papers may vary.

(Exp. Date due to oxidizer test life span.)

INTERFERENCES

Concentrated acidic solutions tend to totally destroy indicators impregnated in papers. Bleeding of the indicator dyes and extreme pH values are good evidence of indicator dye destruction. In the event of such a strong solution dilution may be needed for an accurate analysis.

Heavy oils may saturate test papers and mask test colors.

Opaque solutions may mask colors.

Lightweight organic solvents may contaminate and cause the blue indicator to bleed in TEST #4 (Chemical) or TEST #3 (Wastewater). Volatile organics may vaporize before reading can be made.

Chemical Classifier:

Test #2 – Oxidizer test-strongly acidic, basic solutions, may cause false positives.

Test #3 – Fluoride test-Chlorates, Bromates and Sulfates result in whitening of the test paper if present in large quantities.

Test #5 – Free HNO2 (not nitrite ions) may cause false positives.

Wastewater Classifier:

Test #6 – Fluoride test-Chlorates, Bromates, and Sulfates result in whitening of the test paper if present in large quantities. Test #6 will give positive results in acidic solutions.

Q: WHAT ARE THE LIMITS OF SENSITIVITY?
Chemical Classifier Strips Wastewater Classifier Strips
Chemical Risk

Limits of Sensitivity

Chemical Risk

Limits of Sensitivity

Acid or Base (pH)

0-13

Acid or Base (pH)

0-13

Oxidizers

1 mg/L (1 ppm)

Petroleum Product/

Organic Solvent

10 mg/L (10 ppm)

Fluoride

20 mg/L (20 ppm)

Hydrogen Sulfide

10 mg/L (10 ppm)

Petroleum Product/

Organic Solvent

10 mg/L (10 ppm)

Nitrite

1 mg/L (1 ppm)

Iodine/Chlorine/

Bromine

1 mg/L (1 ppm)

Nitrate

10 mg/L (10 ppm)

 

Fluoride

20 mg/L (20 ppm)

Q: WHO USES CLASSIFIER STRIPS/KITS?
Environmental Cleanup, Construction, Fire/EMS, Industrial/Manufacturing Plants, Metal Fabricating, Military, Municipalities, Gov't, Paper Companies, Petroleum Companies/Refineries, Theme Parks, Utility
ACID NEUTRALIZERS: (BACK TO TOP) MSDS | Download in PDF:
Many aggressive liquid spills involve hazardous acids that require a way to render them safe for final clean-up and disposal in accordance with local, state and federal regulations. KOLOR-SAFE® Acid Neutralizers meet this requirement. KOLOR-SAFE® products provide a unique 3-color change during the neutralization process to indicate when an acid has reached its “neutral” state. Available in both liquid & dry formulas.
LIQUID ACID NEUTRALIZATION CHART
 

Concentration

Volume

(1qt. Neutralizes)

Approx. Amount

Required

To handle 1 gal. (3.785L)

Acid

% by Wgt

Molarity

Pints

Liters

Gallons

Liters

Sulfuric

98

18

0.29

0.14

7.3

27.7

(H2SO4)

50

9.2

0.59

0.28

3.7

14

 

10

1.8

3

1.44

0.9

2.8

             

Nitric

68

15.8

0.69

0.33

3.2

12.2

(HN03)

40

9.3

1.16

0.55

1.9

7.2

 

10

2.3

4.83

2.29

0.5

1.8

             

Acetic

100

17.5

0.61

0.29

3.6

13.7

(CH3COOH)

78

13.7

0.78

0.37

2.8

10.6

 

40

7

1.58

0.75

1.4

5.3

             

Phosphoric

85

14.6

0.25

0.12

8.8

33.3

(H3PO4)

40

6.9

0.52

0.25

4.2

15.9

 

10

1.7

2.02

0.96

1.1

4.2

             

Hydrochloric

40

12

0.92

0.44

2.4

9.1

(HCI)

20

6

1.85

0.88

1.2

4.6

 

10

3

3.71

1.76

0.6

2.3

             

Hydrofluoric

50

28.7

0.38

0.18

5.8

22

(HF)

20

11.5

0.95

0.45

2.3

8.7

 

10

5.7

1.85

0.88

1.2

4.6

DRY ACID NEUTRALIZATION
 

Concentration

   
Acid

% by Wgt

Molarity

Pints

Liters

Lbs.

Kg

Sulfuric

98

18

0.99

0.47

16.1

7.3

(H2SO4)

50

9.2

1.96

0.93

8.1

3.7

 

10

1.8

10.03

4.75

1.6

0.7

             

Nitric

68

15.8

2.28

1.08

7

3.2

(HN03)

40

9.3

3.88

1.84

4.1

1.9

 

10

2.3

15.72

7.44

1

0.5

             

Acetic

100

17.5

2.04

0.97

7.8

3.5

(CH3COOH)

78

13.7

2.62

1.24

6.1

2.8

 

40

7

5.15

2.44

3.1

1.4

             

Phosphoric

85

14.6

0.82

0.39

19.4

8.8

(H3PO4)

40

6.9

1.73

0.82

9.2

4.2

 

10

1.7

7.07

3.35

2.3

1

             

Hydrochloric

40

12

3

1.42

5.3

2.4

(HCI)

20

6

6.02

2.85

2.7

1.2

 

10

3

12.04

5.7

1.3

0.6

KOLOR-SAFE® Dry Hydrofluoric Acid Neutralization Chart

(Special Order Only)

 

Concentration

Volume

(2# Neutralizes)

Approx. Amount Required to handle 1 gal. (3.785L)
Acid

% by Wgt

Molarity

Pints

Liters

Lbs.

Kg

Hydrofluoric

50

28.7

1.79

0.85

8.8

4

(HF)

20

11.5

4.47

2.12

3.5

1.6

             
GRAB&GO® PORTABLE SPILL KITS are also available with Hazmat, Oil Only, and Cellulose-Based Sorbents.CAUTION: Use of KOLOR-SAFE® Dry Acid Neutralizer on higher concentrated acids will cause the release of gases. It is recommended that KOLOR-SAFE® Liquid Acid Neutralizer be used for this purpose. All KOLOR-SAFE® Neutralizers comply with D.O.T. Regulations.
Q: WHO USES ACID NEUTRALIZERS?
Environmental Cleanup, Construction, Industrial/Manufacturing Plants, Metal Fabricating, Military, Municipalities, Gov't, Paper Companies, Printing Industries
BASE NEUTRALIZERS(BACK TO TOP) MSDS | Download in PDF:

Many aggressive liquid spills involve hazardous bases that require a way to render them safe for final clean up and disposal in accordance with local, state and federal regulations. KOLOR-SAFE® Base Neutralizers meet this requirement. KOLOR-SAFE® products provide a unique 3-color change during the neutralization process to indicate when a base has reached its “neutral” state. Available in liquid & dry formulas.

LIQUID BASE NEUTRALIZATION CHART

 

Concentration Volume

(1 qt. Neutralizes)

Approx. Amount Required

to handle 1 gal. (3.785L)

Base Spill

Base

% by Wgt

Molarity

Pints

Liters

Gallons

Liters

Ammonium

61.7 (30% NH3)

14.8

1.11

0.52

1.8

6.9

Hydroxide

42.2 (20% NH3)

9.8

1.66

0.78

1.2

4.6

(NH4OH)

20.6 (10% NH3)

4.9

3.33

1.57

0.6

2.3

 

10.3 (5% NH3)

2.4

6.65

3.15

0.3

1.2

 

 

 

 

 

 

 

Potassium

50

13.4

1.24

0.59

1.6

6.1

Hydroxide

40

10.7

1.53

0.72

1.3

5

(KOH)

20

5.3

2.85

1.35

0.7

2.7

 

10

2.6

6.65

3.15

0.3

1.2

 

 

 

 

 

 

 

Sodium

50

19.2

0.86

0.41

2.3

8.8

Hydroxide

40

15.3

1.05

0.49

2

7.6

(NaOH)

30

11.5

1.42

0.67

1.5

5.7

 

10

3.8

3.99

1.89

0.5

1.9

 

 

 

 

 

 

 

DRY BASE NEUTRALIZATION CHART

 

Concentration Volume

(2# Neutralizes)

Approx. Amount Required

to handle 1 gal. (3.785L)

Base Spill

Base

% by Wgt

Molarity

Pints

Liters

Lbs.

kg

Ammonium

61.7 (30% NH3)

14.8

2

0.95

8

3.6

Hydroxide

42.2 (20% NH3)

9.8

3.04

1.44

5.3

2.4

(NH4OH)

20.6 (10% NH3)

4.9

6.08

2.88

2.6

1.2

 

10.3 (5% NH3)

2.4

12.46

5.9

1.3

0.6

 

 

 

 

 

 

 

Potassium

50

13.4

2.21

1.05

7.2

3.3

Hydroxide

40

10.7

2.78

1.32

5.6

2.6

(KOH)

20

5.3

5.64

2.67

2.8

1.3

 

10

2.6

11.49

5.44

1.4

0.6

 

 

 

 

 

 

 

Sodium

50

19.2

1.54

0.73

10.4

4.7

Hydroxide

40

15.3

1.94

0.92

8.3

3.8

(NaOH)

30

11.5

2.59

1.23

6.2

2.8

 

10

3.8

7.86

3.72

2

0.9

 

 

 

 

 

 

 

CAUTION: Do not use KOLOR-SAFE® Liquid or Dry Base Neutralizer on metallic nitrates, cyanides, strong oxidizers or hypochlorite (calcium or sodium) solutions as dangerous gases will be generated. All KOLOR-SAFE® Neutralizers comply with D.O.T. Regulations.

 
Q: WHO USES BASE NEUTRALIZERS?
Environmental Cleanup, Construction, Industrial/Manufacturing Plants, Metal Fabricating, Military, Municipalities, Gov't, Paper Companies, Printing Industries
BATTERY ACID SPILL CONTROL (BACK TO TOP) MSDS | Download in PDF:
Spilfyter® offers a variety of products designed to handle battery acid (electrolyte) spills. Products offered include: Battery Acid Spill Kit, Battery Acid Wipe, & the Compact Neutralizer Spill Kit. In fact, OSHA Regulations (Standards - 29 CFR) lists electrolyte spill control contingency plans as mandatory:
Powered industrial trucks. - 1910.178 1910.178(g)(2) Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.
Q: WHERE ARE GOOD LOCATIONS FOR BATTERY ACID SPILL CONTROL PRODUCTS?
Place Battery Acid Spil Kit/Compact Neutralizer Spill Kit in strategic locations for quick response to leaking or spilled battery acid. Ideal locations include garages, forklift storage areas, battery storage areas, etc. Also effective for clean-up of dry cell batteries.
Q: HOW DO I USE THE BATTERY ACID & COMPACT NEUTRALIZER SPILL KIT?

1.Evacuate employees from the spill area.

2.Personal protective equipment supplied in the kit should be worn.

3.Ventilate the contaminated area.

4.Spray the spill with Kolor-Safe® Liquid Acid Neutralizer until the spill is pink in color as indicated on the neutralizer bottle. The pink color signifies neutralization of the spill.

5.Once the spill is neutralized, sprinkle Aqualockit® onto the spill. The spill will gel for easy clean-up.

6.Use the scoop with detachable scraper to collect the gelled spill and place used pads in the temporary disposal bag.

7.Use the Hazmat pads to absorb any remaining neutralized spill and place used pads in the temporary disposal bag.

8.Dispose of all materials in accordance with local, state and federal regulations.

Kit Neutralization Capacity: 1 Gallon, Kit Sorbency Capacity: 1.5 Gallons

NOTE: Depending on the size and extent of the spill, additional equipment may be needed. The neutralization capacity depends on the type and concentration of the acid.

WARNING: Once this kit is used to pick up a spilled liquid, the sorbents used will take on the characteristics of the chemical sorbed and should be handled accordingly. CAUTION: This system is to be used by personnel trained in spill clean-up.

 

NPS now offers a unique product called the Battery Acid Neutralizer Wipe-a wipe designed specifically for cleaning corroded batteries!
HANDS-IN-BAG® ATMOSPHERIC CHAMBER (BACK TO TOP) MSDS | Download in PDF:

HANDS-IN-BAG® Atmospheric Chambers provide a convenient portable and inexpensive alternative to a “glove box”. Made from high-clarity polyethylene film which can be sealed, purged and when inflated with an appropriate inert gas allows for handling of air/moisture-sensitive chemicals as well as other hazardous and toxic materials or applications that require a dust-free or controlled-atmospheric environment.

Q: HOW DO I USE HANDS-IN-BAG® ATMOSPHERIC CHAMBER?

1.Unfold and spread out the Hands In Bag® as depicted in diagram to the right.

2.Snip one purging tube opening and insert the gas line from the gas cylinder through the purging tube. Seal the purging tube to the gas line with tape.

3.Load the Hands In Bag® with whatever equipment you may need to perform the given task. If using an electrical cord, place the cord through the additional purging tube and seal the purging tube to the cord. If you use a microscope, cut a port to accommodate the optical piece. Seal with tape. Purge to eliminate room atmosphere. Use pressure regulator.

4.With Hands In Bag® loaded and purged, seal the chamber using the special tape provided. Remove protective backing from tape. Turn back tape 2cm from each end and adhere to work surface. Place the chamber opening over one-half of the width of the tape. Fold remaining half of the tape over the top half of the Hands In Bag® opening. Starting from the center, press firmly, being sure to seal the chamber completely. Tape should extend approximately 2 inches (5 cm) beyond the sides of the chamber opening.

5.Do not over-inflate Hands In Bag®. If you only inflate enough to maintain a billowed shape, it is much easier to do your work.

6.Insert hands in gloves and begin work.

7.Hands In Bag® is designed to fit most laboratory hoods or other controlled systems. Do not use for handling toxic materials except in a hood or other controlled systems to prevent and protect against exposure resulting from leakage.

8.When your work is completed, fold and store your Hands In Bag® for future use. If your Hands In Bag® is contaminated, dispose of it as required.

HANDS IN BAG® Atmospheric Chamber Specifications

 

NOT INFLATED (in.)

INFLATED (in.)

GAS VOLUME

Chamber Size

Opening

Length Width

Opening

Length

Width

Cubic in.

Liters

Large

36

58

51

40

42

18

30240

495

Medium

24

48

39

28

32

16

14336

234

Small

12

30

27

20

24

8

3840

62

4Handed

36

58

51

40

42

18

32000

520

NOTE: All HANDS IN BAG® Atmospheric Chambers are individually packaged with two (2) sealing tape strips. Small HANDS IN BAG® has only two (2) gas or vacuum inlets. Devices for sealing the bags are included in each case. Ethylene oxide treated HANDS IN BAG® Atmospheric Chambers are also available.

CAUTION: HANDS IN BAG® are to be used in conjunction with a fume hood as they are designed to protect the contents inside the bag and not the user. Care should be taken when working with products constructed from polyethylene film due to potential tearing, breaking or punctures. Testing and monitoring of the HANDS IN BAG® for leaks before and during use is strongly recommended. NPS Corporation recommends users read and follow the instructions printed on the package prior to using any HANDS IN BAG® Atmospheric Chamber.

KOLOR-LOCK® SOLIDIFIERS: (BACK TO TOP) MSDS | Download in PDF:
Many aggressive liquid spills involve hazardous acids that require a way to render them safe for final clean up and disposal in accordance with local, state and federal regulations. KOLOR-LOCK® Acid Solidifying Neutralizers meet this requirement. KOLOR-LOCK® takes the guesswork out of knowing when an acid spill is neutralized through its unique 3-color change indicator process. Solidifies the spill for quick and convenient disposal.

Q: HOW DO I USE KOLOR-LOCK® SOLIDIFIERS?

1.Wear required protective clothing and equipment when cleaning up acid spills.

2.Determine the concentration level of the acid and apply appropriate KOLOR-LOCK™ product.

3.Sprinkle KOLOR-LOCK™ on the spill. The spill will change color during neutralization. Continue to apply KOLOR-LOCK™ until the neutralized color is as it appears on the label.

4.Some mixing may be required as KOLOR-LOCK™ solidifies as it neutralizes.

5.Allow neutralized solid to cool.

6.Sweep or shovel the neutralized solid and dispose of according to local, state and federal regulations.

7.Wipe up residue with a damp, non- woven fabric cloth.

8.NOTE: Very concentrated solutions will yield solid precipitates before the color change.

Q: HOW MUCH WILL 2LBS. OF PRODUCT NEUTRALIZE?
2 lbs. Neutralizes approximately:

   

Concentration

Volume

Acid Product

% by Wgt.

Molarity

Pints

Liters

Sulfuric

 

98

18

   

(H2SO4)

A

50

9.2

1.6

0.76

 

B

10

15.8

4.79

2.27

           

Nitric

A

68

15.8

1.92

0.91

(HN03)

A

40

9.3

3.2

1.51

 

B

10

2.3

6.39

3.02

           

Acetic

A

100

17.5

1.28

0.6

(CH3COOH)

A

78

13.7

1.92

0.91

 

A

40

7

3.2

1.51

           

Phosphoric

 

85

14.6

   

(H3PO4)

A

40

6.9

1.74

0.82

 

B

10

1.7

4.79

2.27

           

Hydrochloric

A

40

12

1.92

0.91

(HCI)

B

20

6

3.2

1.51

 

B

10

3

6.39

3.02

           
AQUALOCKIT® SOLIDIFIER: (BACK TO TOP)
AQUALOCKIT® Solidifier is a gelling compound made from a special type of polymer that is ideal for fast, easy and effective clean up of contaminated water, sludge, neutralized acid or base or low-level radioactive water. Once gelled, disposal is easy with a broom and a shovel.

Q: HOW DO I USE AQUALOCKIT® SOLIDIFIER?

1.Evacuate employees from the spill area, if necessary.

2.Wear personal protective equipment compatible with chemicals involved.

3.Ventilate the contaminated area.

4.Determine if the contaminated water, sludge, neutralized acids or bases, etc. are pH neutral (pH 6-7).

5.Sprinkle some of the AQUALOCKIT® onto the neutral spill.

6.Allow the AQUALOCKIT® to absorb the pH neutral liquid.

7.Collect the used AQUALOCKIT® by sweeping, vacuuming, shoveling, etc.

8.Place the used AQUALOCKIT® into a temporary disposal device.

9.Dispose of all used articles according to local, state, and federal regulations.

NOTE: AQUALOCKIT® Solidifier will not gel spills that are not pH neutral. It is strongly recommended that KOLOR-SAFE® Dry or Liquid Neutralizer be used to neutralize the spill prior to use of AQUALOCKIT® for maximum performance.

Q: WHAT ARE THE PRODUCT SORBENCY RATES FOR AQUALOCKIT?

Product Number

Product Description

Qty/Case

Gal. Sorbed Per Case

Liters Sorbed Per Case

670001

AQUALOCKIT® Shaker Bottle, 2#

10

320

1211

670015

AQUALOCKIT® Bulk, 15#

1

240

908

FORMALDEHYDE SOLIDIFIERS: (BACK TO TOP)
Formaldehyde Solidifier is designed for the safe and quick response to formaldehyde spills in laboratories, hospitals, funeral homes, clinics, etc. Formaldehyde Spill Control Products are perfect for spill prone areas that utilize formaldehyde as it reduces toxic vapors, neutralizes the formaldehyde and solidifies the formaldehyde for easy disposal.

WASTE DISPOSAL METHOD:All SPILFYTER® Sorbents in themselves are considered to be non-hazardous as defined by RCRA (40 CFR 261). Once used, these products will take on the characteristics of the chemical sorbed and should be disposed of accordingly. Disposal of these products (used and unused) must be in compliance with all local, state and federal regulations.

NOTE: ASTM F726-8 Standard Method of Testing Sorbent Performance of Adsorbents was used. All sizes, weights and other related information are within the manufacturer’s specifications

 
Q:WHAT ARE THE PRODUCT SORBENCY RATES FOR FORMALDEHYDE SOLIDFIERS?
Product Number

Product

Description

Qty/Case Gal. Sorbed per Case Liters Sorbed per Case

480001

Formaldehyde Solidifier, Shaker

1

0.2

1

480005

Formaldehyde Solidifier, 37#

1

7

25

481001

Fo